{"created":"2023-06-19T10:27:26.472143+00:00","id":274,"links":{},"metadata":{"_buckets":{"deposit":"f8e8c0cf-b349-41fe-84d0-92aa23aa6ddf"},"_deposit":{"created_by":13,"id":"274","owners":[13],"pid":{"revision_id":0,"type":"depid","value":"274"},"status":"published"},"_oai":{"id":"oai:kusw.repo.nii.ac.jp:00000274","sets":["7:20:43:54"]},"author_link":["156"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"21","bibliographicPageStart":"17","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"ヒューマンケア研究学会誌"},{"bibliographic_title":"The Journal of Japanese Society of Human caring Research","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"米国Clinical and Laboratory Standards Institute(CLSI)は,駆血帯を巻いた時の適切な駆血圧について,血圧計などのマンシェットを使用した場合,40mmHgを推奨している.この理由としてCLSIは,末梢血流の阻害を考慮するためとしているが,その明確な根拠は示されていない.我々の行った先行研究では,駆血圧としてCLSIが推奨する40mmHgよりも60mmHgの方が末梢静脈の拡張が良好なため,静脈穿刺を想定した際にもより効果的であることが示唆された.本研究では,超音波診断装置を用いて,加圧に伴う末梢動脈血流阻害を検証した.健常成人10名を対象に20・40・60・80・100mmHgの加圧を行い,橈骨動脈の最高血流速度を計測した.その結果,駆血圧40 mmHgと60mmHgの橈骨動脈最高血流速度は,ほぼ等しく有意差は認められなかった.以上より,若年健常成人の場合,血圧計のマンシェットを用いた駆血圧は60mmHgでも適当であることが示された.","subitem_description_type":"Abstract"}]},"item_10001_heading_23":{"attribute_name":"見出し","attribute_value_mlt":[{"subitem_heading_banner_headline":"研究報告","subitem_heading_language":"ja"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"ヒューマンケア研究学会"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2187-2813","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"佐々木, 新介"}],"nameIdentifiers":[{"nameIdentifier":"156","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-04-23"}],"displaytype":"detail","filename":"4_2_03佐々木.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"本文(PDFファイル)","url":"https://kusw.repo.nii.ac.jp/record/274/files/4_2_03佐々木.pdf"},"version_id":"70217197-d214-48e9-88d2-f158ce914009"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"駆血圧","subitem_subject_scheme":"Other"},{"subitem_subject":"血流速度","subitem_subject_scheme":"Other"},{"subitem_subject":"超音波診断装置","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"末梢静脈穿刺に適切な駆血圧に関する検証 ~加圧に伴う橈骨動脈血流速度の変化~","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"末梢静脈穿刺に適切な駆血圧に関する検証 ~加圧に伴う橈骨動脈血流速度の変化~"}]},"item_type_id":"10001","owner":"13","path":["54"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-04-23"},"publish_date":"2013-04-23","publish_status":"0","recid":"274","relation_version_is_last":true,"title":["末梢静脈穿刺に適切な駆血圧に関する検証 ~加圧に伴う橈骨動脈血流速度の変化~"],"weko_creator_id":"13","weko_shared_id":-1},"updated":"2023-06-19T10:42:18.412720+00:00"}