WEKO3
アイテム
{"_buckets": {"deposit": "7e641e6a-57c2-4349-87de-18813ff8c302"}, "_deposit": {"created_by": 13, "id": "708", "owners": [13], "pid": {"revision_id": 0, "type": "depid", "value": "708"}, "status": "published"}, "_oai": {"id": "oai:kusw.repo.nii.ac.jp:00000708", "sets": ["189"]}, "author_link": ["1106", "1104", "1105", "1107"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "96", "bibliographicPageStart": "93", "bibliographicVolumeNumber": "23", "bibliographic_titles": [{"bibliographic_title": "関西福祉大学研究紀要"}, {"bibliographic_title": "The journal of Kansai University of Social Welfare", "bibliographic_titleLang": "en"}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "関西福祉大学における自動体外式除細動器(AED)の設置状況を明らかにすることを目的とした。調査1 では,インターネットを用いた調査と現地調査を実施し,大学内のAED の設置場所,使用時間帯制限の有無および設置方法について明らかにした。AED は5 カ所に設置されており,大学の全敷地が,いずれかのAED 設置場所を中心にした半径150m の円にカバーされたが,24 時間アクセスが可能なAEDは2 機のみであり,グラウンドの一部が,24 時間アクセス可能なAED 設置場所から1 分以内の範囲外にあることが明らかになった。調査2 では,4 名の成人男性を対象とし,AED 設置場所までの往復所要時間を測定した。実施ルートは,1)最上階である5 階~ 1 階のAED 設置場所(R1),2)屋外のAED 設置場所を中心にした半径150m の円外にあり,AED までの直線距離が最も長いブルペン練習場~最寄りの屋外AED 設置場所(R2),3)屋外のAED から最も遠いエリアにある西側職員駐車場~最寄りの屋外AED 設置場所(R3)とした。AED 設置場所までの歩行による所要時間は,それぞれ,R1 が94.94 ~ 117.86 秒,R2 が176.30 ~ 198.18 秒,R3 が211.21 ~ 251.77 秒であった。調査1 および調査2 の結果から,9.0 ㎞ /hで歩行,あるいは走行できる者であれば,建物内のいずれの場所からも片道1 分以内で到着できる場所に\nAED が設置されているものの,夜間および週末等の建物施錠時においては,9.0 ㎞ /h での歩行,あるいは走行で1 分以内に24 時間アクセス可能なAED に到着することが困難な場所が,複数,存在することが明らかになった。夜間および週末等の建物施錠時においても,1 分以内にAED 設置場所に到着できる確率を高めるためには,AED 設置場所の変更に加え,自転車等の配置なども検討する必要があるものと考える。", "subitem_description_type": "Abstract"}]}, "item_10002_heading_23": {"attribute_name": "見出し", "attribute_value_mlt": [{"subitem_heading_banner_headline": "資料", "subitem_heading_language": "ja"}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "関西福祉大学研究紀要編集委員会"}]}, "item_10002_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12389350", "subitem_source_identifier_type": "NCID"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "24326828", "subitem_source_identifier_type": "ISSN"}]}, "item_10002_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "吉岡, 哲"}], "nameIdentifiers": [{"nameIdentifier": "1104", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大沼, 勇人"}], "nameIdentifiers": [{"nameIdentifier": "1105", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山口, 幸一"}], "nameIdentifiers": [{"nameIdentifier": "1106", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本, 浩二"}], "nameIdentifiers": [{"nameIdentifier": "1107", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-12-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "23-11吉岡.pdf", "filesize": [{"value": "953.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 953900.0, "url": {"label": "本文(PDFファイル)", "url": "https://kusw.repo.nii.ac.jp/record/708/files/23-11吉岡.pdf"}, "version_id": "f8e8de17-9ccc-40a3-b5b5-05de9a780010"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "AED", "subitem_subject_scheme": "Other"}, {"subitem_subject": "24 時間アクセス", "subitem_subject_scheme": "Other"}, {"subitem_subject": "大学内", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "関西福祉大学における自動体外式除細動器の配置状況", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "関西福祉大学における自動体外式除細動器の配置状況"}, {"subitem_title": "Installation Situation of Automated External Defi brillator in Kansai University of Social Welfare", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "13", "path": ["189"], "permalink_uri": "https://kusw.repo.nii.ac.jp/records/708", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-12-25"}, "publish_date": "2020-12-25", "publish_status": "0", "recid": "708", "relation": {}, "relation_version_is_last": true, "title": ["関西福祉大学における自動体外式除細動器の配置状況"], "weko_shared_id": -1}
関西福祉大学における自動体外式除細動器の配置状況
https://kusw.repo.nii.ac.jp/records/708
https://kusw.repo.nii.ac.jp/records/708c3aa2a90-2689-47f7-a8ec-15cdf397da38
名前 / ファイル | ライセンス | アクション |
---|---|---|
本文(PDFファイル) (953.9 kB)
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-12-25 | |||||
タイトル | ||||||
タイトル | 関西福祉大学における自動体外式除細動器の配置状況 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Installation Situation of Automated External Defi brillator in Kansai University of Social Welfare | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | AED | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 24 時間アクセス | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 大学内 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
吉岡, 哲
× 吉岡, 哲× 大沼, 勇人× 山口, 幸一× 山本, 浩二 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 関西福祉大学における自動体外式除細動器(AED)の設置状況を明らかにすることを目的とした。調査1 では,インターネットを用いた調査と現地調査を実施し,大学内のAED の設置場所,使用時間帯制限の有無および設置方法について明らかにした。AED は5 カ所に設置されており,大学の全敷地が,いずれかのAED 設置場所を中心にした半径150m の円にカバーされたが,24 時間アクセスが可能なAEDは2 機のみであり,グラウンドの一部が,24 時間アクセス可能なAED 設置場所から1 分以内の範囲外にあることが明らかになった。調査2 では,4 名の成人男性を対象とし,AED 設置場所までの往復所要時間を測定した。実施ルートは,1)最上階である5 階~ 1 階のAED 設置場所(R1),2)屋外のAED 設置場所を中心にした半径150m の円外にあり,AED までの直線距離が最も長いブルペン練習場~最寄りの屋外AED 設置場所(R2),3)屋外のAED から最も遠いエリアにある西側職員駐車場~最寄りの屋外AED 設置場所(R3)とした。AED 設置場所までの歩行による所要時間は,それぞれ,R1 が94.94 ~ 117.86 秒,R2 が176.30 ~ 198.18 秒,R3 が211.21 ~ 251.77 秒であった。調査1 および調査2 の結果から,9.0 ㎞ /hで歩行,あるいは走行できる者であれば,建物内のいずれの場所からも片道1 分以内で到着できる場所に AED が設置されているものの,夜間および週末等の建物施錠時においては,9.0 ㎞ /h での歩行,あるいは走行で1 分以内に24 時間アクセス可能なAED に到着することが困難な場所が,複数,存在することが明らかになった。夜間および週末等の建物施錠時においても,1 分以内にAED 設置場所に到着できる確率を高めるためには,AED 設置場所の変更に加え,自転車等の配置なども検討する必要があるものと考える。 |
|||||
書誌情報 |
関西福祉大学研究紀要 en : The journal of Kansai University of Social Welfare 巻 23, p. 93-96, 発行日 2020-03 |
|||||
出版者 | ||||||
出版者 | 関西福祉大学研究紀要編集委員会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 24326828 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12389350 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
見出し | ||||||
大見出し | 資料 | |||||
言語 | ja |